Senseca Pro MCP Server

Developer ToolsLow Risk10.0MCP RegistryLocal
Free

Server data from the Official MCP Registry

Live readings from Senseca PRO 111/115 Pt100 thermometers via USB (unofficial)

About

Live readings from Senseca PRO 111/115 Pt100 thermometers via USB (unofficial)

Security Report

10.0
Low Risk10.0Low Risk

Valid MCP server (3 strong, 1 medium validity signals). No known CVEs in dependencies. Package registry verified. Imported from the Official MCP Registry.

10 files analyzed · 1 issue found

Security scores are indicators to help you make informed decisions, not guarantees. Always review permissions before connecting any MCP server.

Permissions Required

This plugin requests these system permissions. Most are normal for its category.

env_vars

Check that this permission is expected for this type of plugin.

What You'll Need

Set these up before or after installing:

Serial port of the instrument, e.g. /dev/ttyACM0 or COM3. Auto-detected if not set.Optional

Environment variable: SENSECA_PORT

Instrument PIN, only needed if its protected mode is enabledRequired

Environment variable: SENSECA_PIN

Set to 1 to enable tools that change instrument settings (clock, location labels)Optional

Environment variable: SENSECA_ALLOW_WRITE

How to Install

Add this to your MCP configuration file:

{
  "mcpServers": {
    "io-github-shaag7967-mcp-server-senseca-pro": {
      "env": {
        "SENSECA_PIN": "your-senseca-pin-here",
        "SENSECA_PORT": "your-senseca-port-here",
        "SENSECA_ALLOW_WRITE": "your-senseca-allow-write-here"
      },
      "args": [
        "mcp-server-senseca-pro"
      ],
      "command": "uvx"
    }
  }
}

Documentation

View on GitHub

From the project's GitHub README.

mcp-server-senseca-pro

An MCP server that lets AI assistants read live measurements from a Senseca PRO 111 / PRO 115 handheld Pt100 thermometer connected via USB.

Unofficial project, not affiliated with or endorsed by Senseca. Tested with a PRO 111, firmware V1.4.3.0, interface protocol V1.0.0.1.

Tools

ToolDescription
read_temperatureCurrent temperature with unit (°C/°F/K, as set on the instrument) and UTC timestamp
read_resistanceCurrent Pt100 resistance in ohm
sample_temperatureReadings over a period (max 600 s, interval ≥ 0.5 s) with min/max/mean/stdev
get_device_infoModel, serial number, firmware, instrument clock, battery level

With --allow-write two more tools are available:

ToolDescription
set_device_clockSet the instrument clock (default: this computer's time)
set_location_nameRename one of the 20 location labels

The server cannot change calibration or adjustment data; the instrument does not offer that over its serial interface.

Requirements

  • Python ≥ 3.10 and uv
  • The instrument switched on and connected via USB-C. On the PRO 115 set Settings → USB mode to COM interface.
  • Linux: your user must be in the dialout group (sudo usermod -aG dialout $USER, then log in again).
  • Windows / macOS: no extra setup; the port shows up as COMx or /dev/cu.usbmodem….

Configuration

Claude Code

claude mcp add senseca-pro -- uvx mcp-server-senseca-pro

Claude Desktop and other clients

{
  "mcpServers": {
    "senseca-pro": {
      "command": "uvx",
      "args": ["mcp-server-senseca-pro"]
    }
  }
}

Options

OptionEnvironment variableDefault
--port PORTSENSECA_PORTauto-detect
--allow-writeSENSECA_ALLOW_WRITE=1off
--log-level LEVELSENSECA_LOG_LEVELWARNING
—SENSECA_PINnone; needed only if the instrument's protected mode is on

Auto-detection looks for USB ID 0483:5740 and only accepts a port whose device reports manufacturer senseca. If several instruments are connected, set the port explicitly; on Linux prefer the stable /dev/serial/by-id/… path.

Only one program can use the serial port at a time. Close ProXware or terminal programs while the server is running.

Measurement notes

  • Instrument accuracy: ±0.05 °C or ±0.06 % of reading (whichever is higher) ±1 digit, probe not included.
  • The USB port is not galvanically isolated. With a probe touching a grounded medium, the USB connection can shift the reading. Compare readings with and without USB, and use a USB isolator if they differ (see the instrument manual, section 7.2).

Development

uv sync
uv run pytest                                   # tests use a simulated instrument
npx @modelcontextprotocol/inspector uv run mcp-server-senseca-pro   # try the tools interactively

To check a real instrument, connect it and run:

uv run python scripts/hardware_test.py               # read-only checks, no interaction
uv run python scripts/hardware_test.py --reconnect   # also unplug/replug USB when asked

The script only sends read commands. See --help for the PIN test.

The serial protocol is described in docs/protocol.md.

License

MIT