Server data from the Official MCP Registry
Measurements with a Siglent SDM3045X bench multimeter via USB or LAN (unofficial)
About
Measurements with a Siglent SDM3045X bench multimeter via USB or LAN (unofficial)
Security Report
Valid MCP server (1 strong, 1 medium validity signals). No known CVEs in dependencies. Package registry verified. Imported from the Official MCP Registry.
6 files analyzed · 1 issue found
Security scores are indicators to help you make informed decisions, not guarantees. Always review permissions before connecting any MCP server.
Permissions Required
This plugin requests these system permissions. Most are normal for its category.
What You'll Need
Set these up before or after installing:
Environment variable: SDM_RESOURCE
Environment variable: SDM_SERIAL
Environment variable: SDM_ALLOW_SCPI
Environment variable: SDM_VISA_BACKEND
How to Install
Add this to your MCP configuration file:
{
"mcpServers": {
"io-github-shaag7967-mcp-server-siglent-sdm3045x": {
"env": {
"SDM_SERIAL": "your-sdm-serial-here",
"SDM_RESOURCE": "your-sdm-resource-here",
"SDM_ALLOW_SCPI": "your-sdm-allow-scpi-here",
"SDM_VISA_BACKEND": "your-sdm-visa-backend-here"
},
"args": [
"mcp-server-siglent-sdm3045x"
],
"command": "uvx"
}
}
}Documentation
View on GitHubFrom the project's GitHub README.
mcp-server-siglent-sdm3045x
An MCP server that lets AI assistants take measurements with a Siglent SDM3045X bench multimeter connected via USB or LAN.
Unofficial project, not affiliated with or endorsed by Siglent. Tested with an SDM3045X, firmware 5.02.01.10, over USB (Linux) and LAN.
Tools
| Tool | Description |
|---|---|
read | One reading with the function and range set on the instrument, keeping them |
measure | Select a function (DC/AC voltage and current, 2/4-wire resistance, capacitance, frequency, period, continuity, diode, temperature) and take one reading |
sample | Timestamped readings over a period (max 600 s, interval ≥ 0.1 s) with min/max/mean/stdev |
burst | Up to 10000 readings as fast as the instrument can (about 180/s at speed fast), with statistics |
get_device_info | Model, serial number, firmware, connection and the present measurement configuration |
Every reading comes with its unit, the range used and, where the data sheet gives a single
figure, its accuracy (e.g. ±(0.06 % of reading + 8 counts) as an absolute value). Overloads
are reported as "overload": true instead of the instrument's 9.9E37.
With --allow-scpi one more tool is available:
| Tool | Description |
|---|---|
scpi | Send any SCPI command or query from the Remote Manual (statistics, limits, null, …) |
The raw SCPI tool is off by default because it can change any setting, including the LAN configuration.
Requirements
-
Python ≥ 3.10 and uv
-
The instrument connected to the USB device port on the rear, or to the network.
-
Linux, USB: the kernel
usbtmcdriver makes the instrument available as/dev/usbtmc0. Give logged-in users access with a udev rule:echo 'SUBSYSTEM=="usbmisc", KERNEL=="usbtmc[0-9]*", TAG+="uaccess"' | sudo tee /etc/udev/rules.d/70-usbtmc.rules sudo udevadm control --reload && sudo udevadm trigger -
Windows / macOS, USB: install a VISA (NI-VISA or Keysight IO Libraries) and start the server with
--visa-backend @ivi. -
LAN: no extra software. The instrument needs an address in your subnet; then the server finds it by itself. On the instrument open Utility → I/O Config → LAN Settings and turn on DHCP, or enter a static IP address, subnet mask and gateway under Modify Settings (User Manual, section I/O Configuration, available on the Siglent product page). Check that the instrument's subnet matches your network: ours came with the static address 10.11.13.220, which the broadcast search does not reach. While USB is connected,
SYST:COMM:LAN:IPAD?(e.g. with thescpitool) shows the address in use.
Configuration
Claude Code
claude mcp add siglent-sdm3045x -- uvx mcp-server-siglent-sdm3045x
# fixed address instead of auto-detection:
claude mcp add siglent-sdm3045x -- uvx mcp-server-siglent-sdm3045x --resource 192.168.1.50
Claude Desktop and other clients
{
"mcpServers": {
"siglent-sdm3045x": {
"command": "uvx",
"args": ["mcp-server-siglent-sdm3045x"]
}
}
}
Options
| Option | Environment variable | Default |
|---|---|---|
--resource RESOURCE | SDM_RESOURCE | auto-detect on USB, then LAN |
--serial SERIAL | SDM_SERIAL | any SDM3045X |
--allow-scpi | SDM_ALLOW_SCPI=1 | off |
--visa-backend BACKEND | SDM_VISA_BACKEND | @py (pyvisa-py) |
--log-level LEVEL | SDM_LOG_LEVEL | WARNING (or DEBUG, INFO, ERROR, CRITICAL) |
RESOURCE can be a device file (/dev/usbtmc0), an IP address or host name (VXI-11), or any
VISA resource string such as TCPIP::192.168.1.50::5025::SOCKET (raw socket) or
USB0::0xF4EC::0x1203::SDM34XXXXXXXXX::INSTR. Port 5024 is a telnet console and does not work
as a socket resource.
Auto-detection tries /dev/usbtmc* first, then Siglent instruments listed by VISA on USB
(leaving out those already asked through /dev/usbtmc*, since pyvisa-py would take them away
from the kernel driver), then VXI-11 instruments in every network this computer is connected to
(UDP broadcast to the portmapper, about 1 s). It accepts the first one that identifies itself as an SDM3045X. With
several instruments, --serial picks one by its serial number (shown by get_device_info, on
the rear label and under Utility → System Setup → System Info). Set --resource instead if
the instrument is in another subnet, where the broadcast does not reach it; the two options
exclude each other.
Measurement notes
- The server cannot see how the test leads are connected. It tells the assistant to only switch to functions that match the wiring: currents need the red lead in the I jack; resistance, continuity, diode and capacitance drive a test current of up to 1 mA through the circuit.
- Switching function or range remotely also changes what the front panel shows.
- Once the server has sent a command, the instrument is in remote mode: the front panel shows "Immediate Trig" and its keys are locked. Press Shift to return to front panel operation. The instrument offers no remote command for this, so the server cannot release it by itself.
- Above 7 A, the data sheet recommends 30 s off after 30 s on.
- Accuracy figures are the one-year data sheet values (23 °C ± 5 °C, 30 min warm-up, speed slow). 2-wire resistance adds 0.2 Ω unless the leads were nulled; AC accuracy depends on the signal frequency and is given per frequency band; thermocouple figures exclude the cold junction error (up to ±3.5 °C with the built-in sensor).
Development
uv sync
uv run pytest # tests use a simulated instrument
npx @modelcontextprotocol/inspector uv run mcp-server-siglent-sdm3045x # try the tools interactively
To check a real instrument, connect it and run:
uv run python scripts/hardware_test.py # voltage-type functions only
uv run python scripts/hardware_test.py --with-test-current # also resistance, current, capacitance, …
uv run python scripts/hardware_test.py --reconnect # also unplug/replug USB when asked
The basic checks only use functions that put no current into the inputs. Observed instrument behaviour, including where it differs from the Remote Manual, is described in docs/protocol.md.
License
MIT
Reviews
No reviews yet
Be the first to review this server!
More Developer Tools MCP Servers
Rea
Freeby Morluto · Developer Tools
Reverse engineer anything from your terminal or agent with one CLI and MCP server.
Paperclip
Freeby Paperclipai · Developer Tools
Trending hip-hop artist momentum scores across four cultural dimensions.
Fetch
Freeby Modelcontextprotocol · Developer Tools
Web content fetching and conversion for efficient LLM usage
Git
Freeby Modelcontextprotocol · Developer Tools
Read, search, and manipulate Git repositories programmatically
Toleno
Freeby Toleno · Developer Tools
Toleno Network MCP Server — Manage your Toleno mining account with Claude AI using natural language.
MCP Marketplace
Freeby mcp-marketplace · Developer Tools
Search and install MCP servers from inside your AI client.